Search Results (15458 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-1960 2026-04-15 9.8 Critical
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an attacker to execute unauthorized commands when a system’s default password credentials have not been changed on first use. The default username is not displayed correctly in the WebHMI interface.
CVE-2023-46565 1 Osrg 1 Gobgp 2026-04-15 7.5 High
Buffer Overflow vulnerability in osrg gobgp commit 419c50dfac578daa4d11256904d0dc182f1a9b22 allows a remote attacker to cause a denial of service via the handlingError function in pkg/server/fsm.go.
CVE-2025-59044 1 Himmelblau-idm 1 Himmelblau 2026-04-15 4.4 Medium
Himmelblau is an interoperability suite for Microsoft Azure Entra ID and Intune. Himmelblau 0.9.x derives numeric GIDs for Entra ID groups from the group display name when himmelblau.conf `id_attr_map = name` (the default configuration). Because Microsoft Entra ID allows multiple groups with the same `displayName` (including end-user–created personal/O365 groups, depending on tenant policy), distinct directory groups can collapse to the same numeric GID on Linux. This issue only applies to Himmelblau versions 0.9.0 through 0.9.22. Any resource or service on a Himmelblau-joined host that enforces authorization by numeric GID (files/dirs, etc.) can be unintentionally accessible to a user who creates or joins a different Entra/O365 group that happens to share the same `displayName` as a privileged security group. Users should upgrade to 0.9.23, or 1.0.0 or later, to receive a patch. Group to GID mapping now uses Entra ID object IDs (GUIDs) and does not collide on same-name groups. As a workaround, use tenant policy hardening to restrict arbitrary group creation until all hosts are patched.
CVE-2025-46599 1 K3s 1 K3s 2026-04-15 6.8 Medium
CNCF K3s 1.32 before 1.32.4-rc1+k3s1 has a Kubernetes kubelet configuration change with the unintended consequence that, in some situations, ReadOnlyPort is set to 10255. For example, the default behavior of a K3s online installation might allow unauthenticated access to this port, exposing credentials.
CVE-2023-6484 1 Redhat 3 Build Keycloak, Red Hat Single Sign On, Rhosemc 2026-04-15 5.3 Medium
A log injection flaw was found in Keycloak. A text string may be injected through the authentication form when using the WebAuthn authentication mode. This issue may have a minor impact to the logs integrity.
CVE-2024-25972 1 Atsumi 1 Oet-213h-bts1 2026-04-15 8.3 High
Initialization of a resource with an insecure default vulnerability in OET-213H-BTS1 sold in Japan by Atsumi Electric Co., Ltd. allows a network-adjacent unauthenticated attacker to configure and control the affected product.
CVE-2024-48122 2026-04-15 6.7 Medium
Insecure default configurations in HI-SCAN 6040i Hitrax HX-03-19-I allow authenticated attackers with low-level privileges to escalate to root-level privileges.
CVE-2025-2029 1 Microdicom 1 Dicom Viewer 2026-04-15 5.3 Medium
A vulnerability was found in MicroDicom DICOM Viewer 2025.1 Build 3321. It has been classified as critical. Affected is an unknown function of the file mDicom.exe. The manipulation leads to memory corruption. The attack needs to be approached locally. It is recommended to upgrade the affected component. The vendor quickly confirmed the existence of the vulnerability and fixed it in the latest beta.
CVE-2025-32074 2026-04-15 5.4 Medium
Improper Encoding or Escaping of Output vulnerability in The Wikimedia Foundation Mediawiki - Confirm Account Extension allows Cross-Site Scripting (XSS).This issue affects Mediawiki - Confirm Account Extension: from 1.39 through 1.43.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-3144 1 Mindspore 1 Mindspore 2026-04-15 3.3 Low
A vulnerability classified as problematic was found in MindSpore 2.5.0. Affected by this vulnerability is the function mindspore.numpy.fft.hfftn. The manipulation leads to memory corruption. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used.
CVE-2024-41995 1 Ricoh Company Ltd 1 Javatm Platform 2026-04-15 7.5 High
Initialization of a resource with an insecure default vulnerability exists in JavaTM Platform Ver.12.89 and earlier. If this vulnerability is exploited, the product may be affected by some known TLS1.0 and TLS1.1 vulnerabilities. As for the specific products/models/versions of MFPs and printers that contain JavaTM Platform, see the information provided by the vendor.
CVE-2024-22041 1 Siemens 13 Cerberus Pro En Engineering Tool, Cerberus Pro En Fire Panel Fc72x, Cerberus Pro En X200 Cloud Distribution and 10 more 2026-04-15 7.5 High
A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates. This could allow an unauthenticated remote attacker to crash the network service.
CVE-2025-36755 1 Cleverdisplay 1 Blueone 2026-04-15 N/A
The CleverDisplay BlueOne hardware player is designed with its USB interfaces physically enclosed and inaccessible under normal operating conditions. Researchers demonstrated that, after cicumventing the device’s protective enclosure, it was possible to connect a USB keyboard and press ESC during boot to access the BIOS setup interface. BIOS settings could be viewed but not modified. This behavior slightly increases the attack surface by exposing internal system information (CWE-1244) once the enclosure is removed, but does not allow integrity or availability compromise under standard or tested configurations.
CVE-2024-29022 2026-04-15 8.8 High
Xibo is an Open Source Digital Signage platform with a web content management system and Windows display player software. In affected versions some request headers are not correctly sanitised when stored in the session and display tables. These headers can be used to inject a malicious script into the session page to exfiltrate session IDs and User Agents. These session IDs / User Agents can subsequently be used to hijack active sessions. A malicious script can be injected into the display grid to exfiltrate information related to displays. Users should upgrade to version 3.3.10 or 4.0.9 which fix this issue. Customers who host their CMS with the Xibo Signage service have already received an upgrade or patch to resolve this issue regardless of the CMS version that they are running. Upgrading to a fixed version is necessary to remediate. Patches are available for earlier versions of Xibo CMS that are out of security support: 2.3 patch ebeccd000b51f00b9a25f56a2f252d6812ebf850.diff. 1.8 patch a81044e6ccdd92cc967e34c125bd8162432e51bc.diff. There are no known workarounds for this issue.
CVE-2025-2851 2026-04-15 8 High
A vulnerability classified as critical has been found in GL.iNet GL-A1300 Slate Plus, GL-AR300M16 Shadow, GL-AR300M Shadow, GL-AR750 Creta, GL-AR750S-EXT Slate, GL-AX1800 Flint, GL-AXT1800 Slate AX, GL-B1300 Convexa-B, GL-B3000 Marble, GL-BE3600 Slate 7, GL-E750, GL-E750V2 Mudi, GL-MT300N-V2 Mango, GL-MT1300 Beryl, GL-MT2500 Brume 2, GL-MT3000 Beryl AX, GL-MT6000 Flint 2, GL-SFT1200 Opal, GL-X300B Collie, GL-X750 Spitz, GL-X3000 Spitz AX, GL-XE300 Puli and GL-XE3000 Puli AX 4.x. Affected is an unknown function of the file plugins.so of the component RPC Handler. The manipulation leads to buffer overflow. It is recommended to upgrade the affected component.
CVE-2025-3017 2026-04-15 5.3 Medium
A vulnerability, which was classified as critical, has been found in TA-Lib up to 0.6.4. This issue affects the function setInputBuffer of the file src/tools/ta_regtest/ta_test_func/test_minmax.c of the component ta_regtest. The manipulation leads to out-of-bounds write. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The identifier of the patch is 5879180e9070ec35d52948f2f57519713256a0f1. It is recommended to apply a patch to fix this issue.
CVE-2025-20010 1 Intel 1 Processor Identification Utility 2026-04-15 7.8 High
Use of unmaintained third party components for some Intel(R) Processor Identification Utility before version 8.0.43 within Ring 3: User Applications may allow an escalation of privilege. System software adversary with an authenticated user combined with a low complexity attack may enable escalation of privilege. This result may potentially occur via local access when attack requirements are not present without special internal knowledge and requires no user interaction. The potential vulnerability may impact the confidentiality (high), integrity (high) and availability (high) of the vulnerable system, resulting in subsequent system confidentiality (none), integrity (none) and availability (none) impacts.
CVE-2025-2441 2026-04-15 4.6 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could lead to loss of confidentiality when a malicious user, having physical access, sets the radio in factory default mode where the product does not correctly initialize all data.
CVE-2025-2442 2026-04-15 6.8 Medium
CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could potentially lead to unauthorized access which could result in the loss of confidentially, integrity and availability when a malicious user, having physical access, sets the radio to the factory default mode.